Minimum Burst Data


Select PSI or Bar:

Mazzer N11 Nylon Tubing

Burst Data at Stated Temperature as PSI

Minimum Burst Data:
N11 Nylon Tubing Fractional Sizes (PSI):

Ref. SizeO.D.
Nom. In.
I.D.
Nom. In.
Wall
Thickness
Nom. In.
Min
Bend
Radius
Minimum Burst Pressure @ Temperature
75°F.100°F.125°F.150°F.175°F.200°F.
N11 21/8.0800.023.701000900800700600500
N11 2.55/32.1060.025.941000900800700600500
N11 33/16.1180.0351.11000900800700600500
N11 41/4.1800.0351.51000900800700600500
N11 4171/4.1700.0401.512001080960840720600
N11 4621/4.1260.0621.5200018001600140012001000
N11 55/16.2330.0401.851000900800700600500
N11 63/8.2750.0502.251000900800700600500
N11 81/2.3750.06331000900800700600500
N11 105/8.5000.0633.75600540480420360300
N11 123/4.5600.0954.5790711632553474395
N11 161.7500.1256790711632553474395

NOTES:  1) The specified minimum bend radius is for minimal tube flattening.  2) The safety factor adopted sets the minimum bursting pressure at four (4) times the working pressure.


Minimum Burst Data:
N11 Nylon Tubing Metric Sizes (PSI):

Ref. SizeO.D.
Nom.
mm
I.D.
Nom.
mm
Wall
Thickness
Nom. mm
Min
Bend
Radius
Minimum Burst Pressure @ Temperature
75°F.100°F.125°F.150°F.175°F.200°F.
N11 042742.70.650241086977869760652543
N11 0402421.0002419561760156513691174978
N11 053353.30.850301015914812711609508
N11 0604641.0003612331110986863740617
N11 0806861.00048841757673589505421
N11 085585.51.250501073966858751644537
N11 10081081.00060609548487426365305
N11 1075107.51.25070827744662579496414
N11 121012101.00075464418371325278232
N11 12091291.50084914823731640548457
N11 141214121.00098392353314274235196
N11 151215121.500105696626557487418348
N11 161316131.500112638574510447383319

NOTES:  1) The specified minimum bend radius is for minimal tube flattening.  2) The safety factor adopted sets the minimum bursting pressure at four (4) times the working pressure.